Profiled roof system


 

  Roof dimensions
(AxB)
Overall external dimensions
(CxD)
Height
(E)
v
Approx. load
capacity (UDL)*
Small roofs 8,5 x 6,5 m 11,3 m x 9,3 m 7,15 m 1800 kg
8,5 x 8,5 m 11,3 m x 11,3 m 7,15 m 1900 kg
9,5 x 9,5 m 12,3 m x 12,3 m 7,15 m 2000 kg
 Medium roofs 10,5 x 8,5 m 13,3 m x 12,3 m 8,15 m 2500 kg
10,5 x 10,5 m 13,3 m x 12,3 m 8,15 m 2900 kg
11,5 x 11,5 m 14,3 m x 14,3 m 8,15 m 3500 kg
12,5 x 10,5 m 15,3 m x 13,3 m 8,15 m 3900 kg
12,5 x 12,5 m 15,3 m x 15,3 m 8,15 m 4000 kg
13,5 x 13,5 m 16,3 m x 16,3 m 10,15 m 4200 kg
 Big roofs 14,5 x 12,5 m 17,3 m x 15,3 m 10,15 m 4500 kg
14,5 x 14,5 m 17,3 m x 17,3 m 10,15 m 4600 kg
18,5 x 14,5 m 21,3 m x17,3 m 12,15 m 6000 kg
20,5 x 14,5 m 23,3 m x 17,3 m 12,15 m 6500 kg

 


 

Small profiled roof system

Small gable roofs offer a simple construction, high safety at a relatively low price. They are one of the most popular in our range. The construction of small gable roofs is mainly based on our HD3 290-Q. The steel tower bases have long outriggers with tower stabilizers. The whole roof construction is easily raised using manual chainhoists. The roof canopy is divided into parts - connected by an aluminum rail on top of arcs.

SMALL ROOFS – TECHNICAL SPECIFICATIONS
Roof structure
Roof dimensions 8,5 x 6,5 m, 8,5 x 8,5 m, 9,5 x 9,5 m
Towers-trussing HD3 290-Q - standard, HD3 390-Q - optional
Main grid-trussing HD3 290-Q - standard, HD3 390-Q - optional
Arch 290-Q - standard, 390-Q - optional
Load capacity (UDL)* 1800-2000 kg
Static calculation In standard
Technical report In standard
Max wind speed 70 km/hv
Design standards Eurocode 1, Eurocode 3, Eurocode 9, DIN 3834-2, DIN 1090-1-2-3
Canopy On top - in standard
Colour - black, blue, gray, green in standard (other colours possible)
Material - fire resistant PCV
Scrims On side and back - in standard
Colour - black (other colours possible)
Material - fire resistant
Chain hoist Manual in standard
Options and customization (on demand)
Fixing Arch to the main grid - By the corners (Arch is located into the main grid – detail A)
- By the fixed couplers AL-50P (Arch is located outside the main grid – deatil B)
Canopy side or/and back
Canopy colors non standard colours – to agree
Scrim non standard colours – to agree
Anemometr optional
Security base frame optional
Ballasts optional
Guy-wire optional
Sound wings optional
Stage platforms optional
Electric hoist optional
Non standard dimensions Project according individual requirements

 


 

Medium profiled roof system

Medium profiled roofs are the most frequently bought by our custo- mers, mainly due to their high stability and the numerous interesting designs available. This makes them an interesting alternative to gable roofs. They are constructed using our HD3 390-Q. The roof construction together with arces is assembled on the ground and raised either by manual or electric hoists. After reaching the desired height the roof is secured to the towers. Rigging wires and belts for side and back walls come as standard to ensure perfect roof stability. Ballast and lines with anchors allow roofs withstands. Every roof can be easily fitted with 2 PA WINGS and LED screens. Medium profiled roofs are the most versatile constructions for small and large events.
 

MEDIUM ROOFS – TECHNICAL SPECIFICATIONS
Roof structure
Roof dimensions 10,5 x 8,5 m, 10,5 x 10,5 m, 11,5 x 11,5 m, 12,5 x 10,5 m, 12,5 x 12,5 m, 13,5 x 13,5 m
Towers-trussing HD3 390-Q - standard
Main grid-trussing HD3 390-Q  - standard, HD4 600x400-Q - optional
Arch 390-Q  - standard, HD3 390-Q - optional
Load capacity (UDL)* 2500-4200 kg
Static calculation In standard
Technical report In standard
Max wind speed 70 km/h
Design standards Eurocode 1, Eurocode 3, Eurocode 9, DIN 3834-2, DIN 1090-1-2-3
Canopy On top - in standard
Colour - black, blue, gray, green in standard (other colours possible)
Material - fire resistant PCV
Scrims On side and back - in standard
Colour - black (other colours possible)
Material - fire resistant
Chain hoist Manual in standard
Options and customization (on demand)
Fixing Arch to the main grid - By the corners (Arch is located into the main grid – detail A)
- By the fixed couplers AL-50P (Arch is located outside the main grid – deatil B)
Canopy side or/and back
Canopy colors non standard colours – to agree
Scrim non standard colours – to agree
Anemometr optional
Security base frame optional
Ballasts optional
Guy-wire optional
Sound wings optional
Stage platforms optional
Electric hoist optional
Non standard dimensions Project according individual requirements

 


 

Big profiled roof system

Our big profiled roofs meet the highest safety standards demanded. Their size, load bearing capabilities and versatility allow for sound and lighting systems along with large displays and branding to be easily mounted making our systems the preferred choice by discerning event organisers for world famous artists. For a edge span we use HD4 600x400-Q. This gives load capacity over 10 tons allowing event organizers to use their creativity to stage stunning memorable events (PICS). Arches are easliy connected to the edge span using specially designed corner attachments, steel wires add extra stability. The whole roof construction is easily lifted using electric hoists. Towers are made by our HD4 390-Q come in two heights - 10 and 12 meters. Every roof can expanded with 2 Pa Wings and LED screens.

BIG ROOFS – TECHNICAL SPECIFICATIONS
Roof structure
Roof dimensions 14,5 x 12,5 m, 14,5 x 14,5 m, 18,5 x 14,5 m, 20,5 x 14,5 m
Towers-trussing HD4 390-Q  - standard
Main grid-trussing HD4 600x400-Q - standard, HD4 390-Q / HD4 800x500-Q - optional
Arch HD3 390-Q  - standard
Load capacity (UDL)* 4500-6500 kg
Static calculation In standard
Technical report In standard
Max wind speed 70 km/h
Design standards Eurocode 1, Eurocode 3, Eurocode 9, DIN 3834-2, DIN 1090-1-2-3
Canopy On top - in standard
Colour - black, blue, gray, green in standard (other colours possible)
Material - fire resistant PCV
Scrims On side and back - in standard
Colour - black (other colours possible)
Material - fire resistant
Chain hoist Manual in standard
Ballasts In standard
Guy-wire In standard
Options and customization (on demand)
Fixing Arch to the main grid - By the corners (Arch is located into the main grid – detail A)
- By the fixed couplers AL-50P (Arch is located outside the main grid – deatil B)
Canopy side or/and back
Canopy colors non standard colours – to agree
Scrim non standard colours – to agree
Anemometr optional
Security base frame optional
Ballasts optional
Guy-wire optional
Sound wings optional
Stage platforms optional
Electric hoist optional
Non standard dimensions Project according individual requirements

 

* - UDL loading cappacity values are average for standard roofs dimmesnion.To increase loading cappacity of each roof system is possible by adding more truss beams to the maingrid, use stronger truss type. Static calculations than are prepared individualy to increase highest loading cappacity.

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.